6ADi4Ro2AVo2AIo
Modbus RTU module with relays and analog outputsChoose it to regulate valves, fans or lights.
- 4 Omron relays, 16 A
- 2 analog outputs 0–10 V and 2 analog outputs 4–20 mA
- 6 inputs, each digital, 0–10 V, 4–20 mA or NTC
- Up to 16 built-in rules. They run without a master.
- Standard Modbus RTU on RS-485
€99 excl. VAT · single unit
Volume and OEM pricing on request · Free shipping in the EU · Ships the same working day
The only model with analog outputs
Relays and analog outputs in one module
- 4 relays switch pumps, fans and heaters
- 4 analog outputs set a position or a speed
- 6 inputs read the sensors
0–10 V and 4–20 mA outputs
- 2 × 0–10 V for valves, dampers and LED dimmers
- 2 × 4–20 mA for variable-speed drives (VFD) and actuators
- The current outputs can also run as 0–20 mA
Up to 16 rules run inside the module
- The rules work without a Modbus master
- Example: a thermostat with an NTC sensor
- If the master goes silent, an analog output can follow a local input again
- The other two models have 8 rules
Typical uses
Heating and ventilation with valves
- Inputs read temperature and pressure sensors
- 0–10 V outputs set valves and dampers
- Relays switch fans and pumps
Pump speed with a variable-speed drive (VFD)
- A 4–20 mA output sets the speed of the drive
- Inputs read flow and pressure
- A relay switches the pump on and off
Take over an existing 4–20 mA signal (VPP)
- Wire the module into an existing 4–20 mA loop
- Normally the output follows the input
- Your platform can override the value over Modbus
- If communication is lost, the output follows the input again
Key Specifications
| Parameter | Value |
|---|---|
| Relay Outputs | 4 × Omron (16 A @ 230 V) |
| Analog Voltage Outputs | 2 × 0–10 V |
| Analog Current Outputs | 2 × 4–20 mA |
| Inputs | 6, each digital, 0–10 V, 4–20 mA or NTC |
| RS-485 | 1 port, Modbus RTU, 300–115200 bps |
| Power Supply | 11–30 V DC |
| Operating Temperature | −40 to +55 °C |
Full Specifications
Inputs
| Parameter | Value |
|---|---|
| Inputs | 6, each digital, 0–10 V, 4–20 mA or NTC |
| Max Input Voltage | 30 V DC |
| Digital Thresholds | Active 2.5–30 V, inactive 0–1.5 V |
| Analog Range | 0–10 V DC, 16-bit |
| Analog Accuracy | ±0.1 % or ±3 mV (whichever greater), 0.05–10 V |
| Sampling Rate | >100 Hz |
| Input Impedance | >5 MΩ |
| 4–20 mA Input | Via external resistor to GND (250 Ω gives 1–5 V, 500 Ω gives 2–10 V) |
| NTC Input | 10 kΩ thermistor (β = 3435 or β = 3977), connected directly |
| Pull-up | 10 kΩ @ 10 V per input, software-enabled |
| Debounce Filter | 50 ms (software) |
| Digital Input Events | Per input: activation counter, single click, double click, long press (>2 s) |
Relay Outputs
| Parameter | Value |
|---|---|
| Relay Outputs | 4 × Omron (16 A @ 230 V) |
| Relay Model | Omron G2RL-1-E. Relays 1–3 SPDT, relay 4 SPST-NO |
| Contact Rating | 250 V AC / 24 V DC, max 16 A (resistive) |
| Mechanical Life | 20 million operations |
| Electrical Life | 30,000 ops @ 16 A 250 V AC, 200,000 ops @ 8 A 250 V AC (cosφ 0.4) |
| Coil Voltage Reduction | Software-controlled |
| Relay Timer | Per relay: switches the relay on for a set number of seconds, over Modbus |
Analog Outputs
| Parameter | Value |
|---|---|
| Analog Voltage Outputs | 2 × 0–10 V |
| Voltage Output Load | ≥1 kΩ, max 10 mA |
| Analog Current Outputs | 2 × 4–20 mA |
| Current Output Range | 0–20 mA (4–20 mA mode selectable via Modbus) |
| Max Loop Impedance | ≤1.0 kΩ at 24 V DC / ≤450 Ω at 12 V DC |
| Isolation | Not isolated (referenced to supply GND) |
| Output Update Rate | >1000 Hz |
Communication
| Parameter | Value |
|---|---|
| RS-485 | 1 port, Modbus RTU, 300–115200 bps |
| Protocol | Modbus RTU slave |
| Baud Rates | 300 / 600 / 1200 / 2400 / 4800 / 9600 / 19200 / 38400 / 57600 / 115200 bps |
| Data Format | 8N1 / 8N2 / 8E1 / 8O1 |
| Factory Default | Address 1 · 9600 bps · 8E1 |
| Modbus Address | 1–247 via Modbus, 1–247 via front-panel buttons |
| Bus Protection | ±30 V on bus pins, ±16 kV ESD (HBM) |
| Network Capacity | Up to 128 modules on one line. Addresses 1–247. |
| Firmware Update | In-field over Modbus |
Local Control
| Parameter | Value |
|---|---|
| Automation Rules | Up to 16, run locally without a Modbus master |
| Rule Types | Toggle relay, Flexible switch, Thermostat (NTC), Analog threshold, Communication-driven voltage failover |
| Rule Storage | Non-volatile, rules survive power cycling |
| Front Panel Buttons | 4 buttons (disable possible) |
| Status Indicators | Input, Relay, RS-485, System LEDs |
Power
| Parameter | Value |
|---|---|
| Input Range | 11–30 V DC |
| Nominal Voltage | 12 V or 24 V DC |
| Idle Consumption | 0.35 W @ 12 V / 0.5 W @ 24 V |
| All Relays On | 1.8 W @ 12 V / 2.1 W @ 24 V with coil voltage reduction, 3.0 W / 3.3 W without |
| Reverse Voltage Protection | Yes, up to 30 V |
Mechanical
| Parameter | Value |
|---|---|
| Mounting | DIN-rail (TH35, EN 60715) |
| Module Size | 6M (6 × 17.5 mm) |
| Dimensions (L × W × H) | 106 × 90 × 58 mm, without DIN-rail clip |
| Install Clearance | ~5 mm below the module for the DIN-rail release clip |
| Weight | 265 g |
| Terminals | Pluggable terminal blocks. Signals ≤1.5 mm². Power, relays ≤2.5 mm² |
Environment & Compliance
| Parameter | Value |
|---|---|
| Operating Temperature | −40 to +55 °C |
| Storage Temperature | −40 to +60 °C |
| Relative Humidity | <90 %, non-condensing |
| Altitude | Up to 2000 m |
| CE Compliance | 2014/30/EU (EMC), 2014/35/EU (LVD) |
| Warranty | 36 months |
Processor
| Parameter | Value |
|---|---|
| CPU | ARM Cortex-M33 @ 76.8 MHz |
Downloads
The JSON files are the full register list. Use them as a Wolf-App template or give them to an AI assistant.
| Document | Format | Size |
|---|---|---|
| Product Manual | PDF ↓ | 2.1 MB |
| Flyer | PDF ↓ | 1.4 MB |
| Setting the Modbus Address (Quick Reference) | PDF ↓ | 2.4 MB |
| Wiring Instructions | PDF ↓ | 5.0 MB |
| Modbus Register List | PDF ↓ | 892 KB |
| Modbus Register List | XLSX ↓ | 1.3 MB |
| Register list as JSON, inputs and outputs (Wolf-App template) | JSON ↓ | 21 KB |
| Register list as JSON, with rule registers (Wolf-App template) | JSON ↓ | 89 KB |
Set the Modbus address with four buttons
Every module leaves the factory on address 1. With the four front-panel buttons you set:
- Modbus address
- Baud rate
- Serial format
No master, no laptop and no software.
The steps are the same as on the 6Ai6Ro. Watch the video on the 6Ai6Ro page →
Two things are different on this model:
- Eight LEDs show the value in binary (
1 · 2 · 4 · 8 · 16 · 32 · 64 · 128) - The buttons reach every address from 1 to 247
The Quick Reference (PDF) in the downloads shows the same steps on one page. It also has the LED pattern for every value.
The other two models and a matching gateway
6Ai6Ro
DI 0–10 V 4–20 mA NTC Relays
Choose it to read sensors. The same inputs, 6 relays and no analog outputs.
6Oi6Ro
Opto-isolated DI Relays
Choose it for on/off signals. 6 opto-isolated digital inputs and 6 relays.
Wolf Gateway
RS-485 Modbus TCP Linux
A Modbus master for these modules. It has a ready template for the 6ADi4Ro2AVo2AIo. It passes the data on as Modbus TCP, REST or MQTT.
Order 6ADi4Ro2AVo2AIo
€99 excl. VAT per unit. Free shipping in the EU. Send the quantity and the delivery address. We ship the same working day. For 10 or more, ask for volume and OEM pricing.