Modbus RTU Relay and I/O Modules

Add inputs and relays to any BMS or PLC.
  • Up to six 16 A Omron relays per module
  • Analog outputs on one model
  • Six inputs per module: digital, 0–⁠10 V, 4–⁠20 mA and NTC
  • Up to 128 modules on one RS-485 line
  • Standard Modbus RTU: function codes 03, 06 and 16
  • Full Modbus register list: PDF, Excel and JSON
  • Works alone too, with built-in rules
Set the address with buttons −40 to +55 °C Designed in the EU 36-month warranty Free EU shipping Ships same day

Three models. Choose by your inputs and outputs.

  • The Modbus registers follow the same pattern on all three
  • Same setup steps and same front-panel buttons for the address
  • Tested and calibrated in Estonia before shipping

6Oi6Ro €79 excl. VAT

Choose it for on/off signals.

  • 6 digital inputs
  • 6 Omron relays, 16 A

Opto-isolated inputs

View Specs

6Ai6Ro €89 excl. VAT

Choose it to read sensors.

  • 6 inputs, each digital or analog
  • 6 Omron relays, 16 A

0–⁠10 V 4–⁠20 mA NTC

View Specs

6ADi4Ro2AVo2AIo €99 excl. VAT

Choose it to regulate valves, fans or lights.

  • 6 inputs, each digital or analog
  • 4 Omron relays, 16 A
  • 4 analog outputs

0–⁠10 V 4–⁠20 mA NTC 0–⁠10 V out 4–⁠20 mA out

View Specs

The differences are in the inputs and outputs

Specs, prices and manual links as plain text. Paste into any AI assistant.
Feature 6Oi6Ro 6Ai6Ro 6ADi4Ro2AVo2AIo
Price (excl. VAT, single unit) €79 €89 €99
Inputs 6 digital, opto-isolated 6, each digital or analog 6, each digital or analog
Analog Input Types – 0–⁠10 V · 4–⁠20 mA · NTC 0–⁠10 V · 4–⁠20 mA · NTC
Relay Outputs 6 × Omron (16 A @ 230 V) 6 × Omron (16 A @ 230 V) 4 × Omron (16 A @ 230 V)
Analog Voltage Outputs – – 2 × 0–⁠10 V
Analog Current Outputs – – 2 × 4–⁠20 mA
Power Supply 9–⁠30 V DC 11–⁠30 V DC 11–⁠30 V DC
Front Panel Buttons 6 (disable possible) 6 (disable possible) 4 (disable possible)
Automation Rules Up to 8 Up to 8 Up to 16
Full Specs & Downloads View 6Oi6Ro View 6Ai6Ro View 6ADi4Ro2AVo2AIo

The same on all three models

Parameter Value
CPU ARM Cortex-M33 @ 76.8 MHz
Relay Type Omron (16 A @ 230 V)
Communication RS-485, Modbus RTU, 300–115200 bps
Mounting DIN-rail
Operating Temperature −40 to +55 °C
Rule Engine Built-in, standalone operation
If the Master Goes Silent The relays go to a state you choose
After a Power Cut The relays start off
Design and Testing Designed in the EU (Estonia). Tested and calibrated in Estonia by FoxIoT
Warranty 36 months
Shipping Free in the EU, ships the same working day

The full register list is ready for every model

  • Modbus register list as PDF and Excel
  • The same registers as JSON, ready to give to an AI assistant
  • Product manual (PDF)
  • Wiring Instructions (PDF)

Get the files: 6Oi6Ro · 6Ai6Ro · 6ADi4Ro2AVo2AIo

Relay registers in the FoxIoT 6ADi4Ro2AVo2AIo Modbus register list

A small part of the 6ADi4Ro2AVo2AIo register list.

  • Relays, inputs and settings are all holding registers
  • Most customers connect the modules to a building management system (BMS)
  • Many customers use our Wolf Gateway. It has ready templates for every model.
  • Any other Modbus master works too

Up to 128 modules on one line. Set each address with buttons.

FoxIoT 6Ai6Ro Modbus RTU modules side by side in an Agatark electrical cabinet, input LEDs lit

6Ai6Ro modules in an Agatark installation. The photo shows the earlier front cover.

One RS-485 line carries up to 128 of these modules. Other devices on the same line lower that number. Each module needs its own address.

Every module leaves the factory on address 1. With several new modules on one line you must change it first.

You set it with the front-panel buttons:

  • Modbus address
  • Baud rate
  • Serial format

No master, no laptop and no software. An installer can do it while mounting the module, before the control system is ready.

Watch the walkthrough →